Zk inbio 480 manual

Manual inbio

Add: vavuqed16 - Date: 2020-12-17 09:28:10 - Views: 5644 - Clicks: 8785

InBio Series; Reader. 5 Current (mA) ZK ELECTRIC LOCK Voltage (V) DC 10. Wiegand inputs are also provided for traditional RFID. ZKAccess US-INBIO-460 Access Control Panel. 4(2 RS-485 Reader, 2 26-bit wiegand reader) 8(4 RS-485 Reader, 4 26-bit wiegand reader) 12 (8 RS-485 Reader, 4 26-bit wiegand reader) Types of readers supported 26-bit Wiegand and RS485 FR Series Reader. Zk Inbio 460 4 Door Fingerprint Card Access Control System carries out the matching of fingerprints on the panel, itself. The Controller stores up to 3,000 fingerprint templates, 30,000 card users, and up to 100,000 events and transactions.

The communication cable should be away from high-voltage lines as far as possible. Kontroler Inbio dapat dipasang dengan mudah pada jaringan anda dan komunikasinya dapat dilakukan baik dengan TCP/IP dan RS-485. La herramienta de búsqueda permite encontrarlos en la red y configurar los parámetros fácilmente. Network Video CMS User Manual V1. eSSL Security is one amongst the leading biometric companies in India and has grown into international territories since inception (). The FR Series of readers transmit fi­ngerprint templates to inBio via RS-485 for fast and accurate matching with templates stored in a data-base.

Data is preserved if power is lost. Fimware Kontroler Inbio dapat diupgrade di lapangan. ZK-MA-300 | ZK-MA-500 | ZK-D100S | ZK-D1065S | TS2200 | TS2100 | TS1200 | ZK-EC10 | INBIO PRO 260 | INBIO PRO 460. The Controller is backed up in real-time to an onboard SD card. User Manual; Installation Guide; Quick Use Guide. Can be store up to 3,000 ­fingerprint templates, 30,000 card users, and up to 100,000 events and transactions. FR1200, a fingerprint reader with RS485 communication interface works with zk inbio 480 manual biometric access controllers and fingerprint standalone access control, including inBIO series controllers, F8 and so on. Véase guía anexa.

Controller is backed up in real-time in on-board SD card. InBio Pro Series Access Control Panels INSTALLATION GUIDE Restore Factory Setting Restore Factory Setting Restore factory setting 1. InBio X60 Series User Manual 4 connect a diode in parallel (please use the FR107 delivered with the system) with the electronic lock to release the self-induced electromotive force. Auto-discovery tool allows parameters directly and easily. Manual del panel de control de acceso InBio 460 de ZKTeco Antonio Evangelista Actualización 14.

7kg Size 350(L) ×90(H) 300(W)mm Specifications InBio-160 InBio-260 InBio-460 Number of doors controller 1 Door 2 Door 4 Door Numbers of readers supported 4(2 RS-485 Reader, 2 26-bit wiegand reader) 8(4 RS-485 Reader, 4 26-bit wiegand reader) 12 (8 RS-485 Reader, 4 26-bit wiegand reader). Dapat menyimpan hingga 3,000 template sidik jari, 30,000 pengguna kartu, dan lebih dari 100,000 kejadian dan transaksi. Control Panel Metal Case Power Supply, DC12V/3A, Available to Charge for Battery Back-up Access Software for Control Panel, User Manual Gross Weight zk inbio 480 manual Number of doors controller Numbers of readers supported Types of readers supported 26-bit Wiegand and RS485 FR Series Reader 26-bit Wiegand and RS485 FR Series Reader 26-bit Wiegand and RS485 FR Series Reader 3(exit Device and Door Status, 1 AUX.

ZK-INBIO480 Módulo de Control de Acceso para 4 puertas Ingreso/Salida con conexión TCP/IP Soporta 3000 zk inbio 480 manual Usuarios: Huella y/o Proximidad La unidad de control IP para 2 o 4 puertas inBIO 480, maneja 4 lectores de proximidad o 8 lectores biométri-cos, wiegand 26 bits, botón salida, botón salida de emergencia, sirenas, magnéticos y retenedores. User Manual 1 ea Gross Weight 3. com All designs and specifications are subject to change without notice TCP/IP Con˜guration RS485 Con˜guration MODEL NUMBER inBio 160 inBio 260 inBio 460. Time and Attendance Management, Time Management Software, Payroll Management, Payroll Management Devices,Time Management Device, Shift Management, Shift Management Devices, Canteen Management, Canteen Management Devices, access Control devices. InBio Fingerprint Access Controller firmware can be upgraded in the field. Fast, reliable performance combined with affordability gives ZK readers the competitive edge. It is recommended that an electronic lock and a control panel should use respective power supplies.

2 Current (mA) InBio Pro Series Access Control Panels INSTALLATION GUIDE. Options InBio controllers come in 3 sizes to suit project needs and reduce the cost of unused capacity. InBio Pro Series | InBio Pro Series is a project oriented high-end product line with unique features such as embedded fingerprint verification and advanced access control functions, which can be managed by TCP/IP communication thru LAN or WAN networks.

K14 is an innovating fingerprint reader for time and attendance applications, offering unparalleled performance using an advanced algorithm for reliability, precision and excellent matching speed. inBio carries out the matching of fi­ngerprints on the panels. Each reader has the capacity to store up to 2,200 fingerprint templates and 30,000 transactions. 1-door, 2-door, and 4-door models can be mixed and matched in an optimized. ZK&39;s goal is. Categoría: Terminales Biométricos Etiquetas: biométrico, huella, lector de huella, terminal.

Related Products. Los paneles se instalan de forma sencilla en la red y soportan comunicación TCP/IP y RS485. Managing our readers is also simple.

Equipment Communication inBIO 480 Installation and Connection Guide The PC software communicate with the system through two protocols (RS485 and TCP/IP) Vision:1. de intrusos, vínculos o control manual. InBio controllers can be installed easily on your network and support both TCP/IP and RS-485 communication. 1 KB) ZKAccess Proximity Cards Data Sheet (Size: 90. inBio controllers come in 3 sizes to suit project needs and reduce the cost of unused capacity. inBio controller fi­rmware can be upgraded in the field. ZKAccess FR1200 User Manual (Size: 726.

ZK Access- ACP-inBio Controller Setup Guide Considerations Prior to Setup Please note the following considerations prior zk to setting up your ACP or inBio controller. El siguiente manual describe el funcionamiento del panel de control inbio 260. Si el FR1200 se alimenta desde el Panel Inbio la longitud del cable debe ser menor a 100 metros o 330 pies 4. The FR Series of readers transmit fingerprint templates to InBio via RS-485 for fast and accurate matching with templates stored in a data-base. Number of doors controller.

1 Date: July, for data exchange and remote management. 5 KB) ZKAccess inBIO Series Data Sheet (Size: 680 KB) ZKAccess inBIO Series User Manual (Size: 10. The FR Series of readers transmit fingerprint templates to inBIO vis RS485 for fast and accurate matching with templates stored in the database. Firmware Requirements: For ACP controllers, the firmware required is 4. 1-door, 2-door, and 4-door models can be mixed and matched in an optimized system architecture.

Truly Internal Biometric Identification. Numbers of readers supported. inBio controllers install easily on your network and support both TCP/IP and RS-485 communication. inBio continues to operate if network connection is interrupted.

inBio Pro Installation Guide. Network Video CMS Quick Start Guide V1. 2(2 RS-485 Reader, 2 26-bit wiegand reader) 4(4 RS-485 Reader, 4 26-bit wiegand reader) 8 (8 RS-485 Reader, 8 26-bit wiegand reader) Types of readers supported 26-bit Wiegand and RS485 FR Series Reader 26-bit Wiegand and RS485 FR. Terminal Biométrica ZK-INBIO 480 Incluye software de control de acceso con funciones de valor agregado, antipassback local, control por proximidad o biometría, salidas y entradas auxiliares. Enrolling users is fast and easy, since most of our readers have a user-friendly keypad and display. inBIO carries out the matching of fingerprints on the panels. La interfaz RS485 externa puede suministrar un máximo de 500 mA de corriente, La corriente de arranque del FR1200 es de 240mA o sea que el Inbio únicamente puede alimentar dos FR1200s ¡SOLO DOS FR1200¡. It offers the function of capturing and transferring fingerprint samples to access control panel.

If you forget the IP address of the InBio Pro panel or the device does not work normally, you can use the number 7 DIP switch to restore InBio Pro Panel to factory default settings. The input ports are pulled Pull- up resistance (Ω) 4. com/Security/Access-Control-Kits/ZK-US-InBio-4-Door-Kit InBio carries out the matching of fingerprints on the panels. It provides abundant functionality that fulfills management requirements of small- to medium-sized businesses: Personnel Management, Access Control, Attendance Management, Video Surveillance, System Management. La serie InBio cuenta con paneles de 1, 2 y 4 puertas para adaptarse a las necesidades del proyecto. 7k resistors WIEgAND INPuT Voltage (V) 10. ZKBio Access IVS is a lite web-based security platform developed by ZKTeco which supports most ZKTeco Hardware.

3 MB) ZKAccess K1 Data Sheet (Size: 57. ZK Access 201 Circle Drive North, Suite 116, Piscataway, NJ 08854, United States com TCP/IP Con˜guration RS485 Con˜guration MODEL NUMBER inBio 160 inBio 260 inBio 460 Number of doors controlled One door Two Door Four Door Number of card readers supportedbit Wiegand.

Zk inbio 480 manual

email: ekukug@gmail.com - phone:(352) 906-7467 x 7720

Manual tefone intelbras - Goma manualidades

-> Baixar manual impressora xerox 3100 mfpx
-> Manual do direito pdf

Zk inbio 480 manual - Manual oven venini


Sitemap 1

Manuale il ciclo delle performance nei comuni - Manual speed transmission xrunner